All-Electric Servo Valve Station

Products/All-Electric Servo Valve Station
Water cooling / continuous-casting secondary cooling · flow and switching control

All-Electric Servo Valve Station

Make cooling control more stable.
Reduce air-supply and maintenance costs.

Combines precision servo control and on/off valves to replace pneumatic valves, solenoid valves and complex air circuits. No continuous air supply is required. Precision positioning, fast opening / slow closing, position feedback and diagnostics provide a monitored actuation platform for water cooling and secondary cooling in continuous casting.

Front view of the valve station with water piping, servo control valve and control cabinet
Valve station · front view
Side view of the same valve station
Valve station · side view
Four Core Benefits

Integrate modulation, switching and feedback.
Improve everyday cooling-water operation.

01 / Operating Costs

Reduce continuous air-supply costs

Direct servo motor drive eliminates continuous air supply at the valve station, reducing compressed-air energy demand and losses from air-circuit leakage.

02 / Cooling Control

Keep water flow aligned with the process

Precise positioning and actual-position feedback reduce the effect of air-supply fluctuations. Integrate with closed-loop temperature control to stabilize cooling.

03 / Spray timing

Spray promptly. Reduce water hammer.

Set opening and closing speeds independently: open quickly when cooling is needed and close gradually to reduce sudden flow changes and pipe stress.

04 / Site Maintenance

Simplify inspection and troubleshooting

Reduce air-circuit maintenance points. View commands, valve position and faults together; automatic calibration simplifies commissioning after installation or maintenance.

Key Performance Data

0.1%

Valve positioning accuracy

ASV bus and local manual modes
≤20ms

Servo motor response time

Prompt response to control commands
<0.4s

Servo on/off valve full-stroke time

At the maximum speed setting

0.1% refers to ASV valve positioning accuracy in bus and local manual modes. ≤20 ms is servo motor response time; the on/off valve full-stroke time is <0.4 s at the maximum speed setting.

Retrofit Comparison

Compared with a pneumatic valve station,
which operating areas can improve?

Focus AreaTraditional Pneumatic Valve StationAll-Electric Servo Valve Station
Energy & Air SupplyContinuous air supply, with compression and leakage lossesMotor drive, without continuous air supply at the station
System MaintenanceAir and electrical circuits, with more peripheral maintenance componentsSimpler air circuits; focus maintenance on electrical and mechanical inspection
Flow & SwitchingValve movement affected by air supply, piping and solenoid valvesPrecision modulation, fast switching and actual-position feedback
Water Hammer ControlClosing-speed adjustment depends on air-circuit conditionsIndependent opening and closing speeds support fast opening / slow closing
Monitoring & IntegrationDistributed operating information; digital communication requires suitable configurationStatus display and diagnostics; 4–20mA, Modbus RS485 and end-position feedback
Selection Questions

Valve station retrofit questions

Does 0.1% valve positioning accuracy specify cooling-temperature accuracy?

No. The 0.1% figure refers to ASV valve positioning in bus and local manual modes. Temperature control also requires measurement feedback and assessment of the complete cooling process. The PLK infrared pyrometer provides workpiece-temperature readings for control feedback.

What should be checked before replacing a pneumatic valve station?

Review water pressure and flow, valve sizes, existing PLC interfaces, spray timing, and the main air-supply or maintenance issues. Use the valve-station retrofit guide to organize the project inputs.

Assess a valve-station retrofit against your cooling needs.

Share water pressure and flow, valve sizes, existing PLC control and the main air-supply or maintenance issues.

Discuss Your Requirements ↗